MPC7447A RISC Microprocessor Hardware Specifications, Rev. 5
Freescale Semiconductor 21
Electrical and Thermal Characteristics
Figure 11 provides the test access port timing diagram.
Figure 11. Test Access Port Timing Diagram
5.3 Voltage and Frequency Derating
To reduce the power consumption of the device, these devices support voltage and frequency derating
whereby the core voltage (V
DD
) may be reduced if the reduced maximum processor core frequency
requirements are observed. The supported derated core voltage, resulting maximum processor core
frequency (f
core
), and power consumption are provided in Table 11. Only those parameters in Table 11 are
affected; all other parameter specifications are unaffected.
Table 11. Supported Voltage, Core Frequency, and Power Consumption Derating
Maximum Rated
Core Frequency
(Device Marking)
Supported
Derated Core
Voltage (V
DD
)
Maximum Derated Core
Frequency (f
core
)
Full-Power Mode Power
Consumption
Maximum Typical
1000 1.20 V ±50mV 867 MHz 15.5 W 10.5 W
1267 1065 MHz 18.2 W 12.3 W
1333 1167 MHz 18.1 W 12.3 W
1420 1267 MHz 21.0 W 14.2 W
V
M
TCK
TDI, TMS
TDO
Output Data Valid
V
M
= Midpoint Voltage (OV
DD
/2)
t
IXJH
t
IVJH
t
JLOV
t
JLOZ
Input
Data Valid
TDO Output Data Valid